By Dimitrios Tsaoulidis

The current paintings specializes in the advance of intensified small-scale extraction devices for spent nuclear gasoline reprocessing utilizing complicated method engineering with mixed experimental and modelling methodologies. It discusses a few novel parts, corresponding to the intensification of spent gas reprocessing and using ionic beverages as eco-friendly possible choices to natural solvents. using ionic beverages in two-phase liquid-liquid separation is new to the Multiphase movement neighborhood, and has proved to be difficult, particularly in small channels, end result of the floor and interfacial homes concerned, that are very assorted to these of universal natural solvents. Numerical reports were additionally played to couple the hydrodynamics at small scale with the mass move. The numerical effects, taken including scale-up reviews, are used to guage the applicability of the small-scale devices in reprocessing huge volumes of nuclear waste.

Show description

Read or Download Studies of Intensified Small-scale Processes for Liquid-Liquid Separations in Spent Nuclear Fuel Reprocessing PDF

Similar nuclear books

Deterrence Now

With shares lowered, and plans revised, family members among states with nuclear arsenals were remodeled after the chilly battle. despite the fact that, Patrick Morgan argues that those adjustments haven't been followed by means of nice advances in our wisdom of even if and the way deterrence works. He for that reason explores the nation of deterrence concept and its carrying on with relevance less than stipulations of nuclear proliferation, collective defense businesses, and a revolution in army affairs.

The Fukushima Daiichi Nuclear Accident: Final Report of the AESJ Investigation Committee

The value nine nice East Japan Earthquake on March eleven, 2011, by means of an important tsunami struck TEPCO’s Fukushima Daiichi Nuclear energy Station and caused an remarkable center melt/severe coincidence in devices 1 – three. The radioactivity free up ended in the evacuation of neighborhood citizens, lots of whom nonetheless haven't been capable of go back to their houses.

The Japanese Social Crisis

Political scandals, governmental instability and the poison-gas assault in significant Tokyo express that Japan is passing via a major social predicament. It impacts almost each social unit: kinfolk, university, corporation, political events, religions and the country. And it concerns each section of the inhabitants, old and young, women and men, administration and labour, the elite and the plebe.

Extra info for Studies of Intensified Small-scale Processes for Liquid-Liquid Separations in Spent Nuclear Fuel Reprocessing

Sample text

2007) investigated the effect of plug length on the formation of internal circulation and they reported the cases where circulation was absent. They found that at short plugs and low flow velocities internal circulation is minimal, since zero velocity gradients exist. Circulation times increased in value as a function of the velocity till a threshold value beyond which the internal circulation no longer increases. For small segments the contribution of the liquid-liquid friction to the phase internal flow is the decisive factor and liquid/wall friction is minimal due to its small contact area (Malsch et al.

2008). The need to use volatile organic compounds (VOCs) as solvents or the subsequent generation of VOCs, introduce safety risks (Visser and Rogers 2003). Recently ionic liquids (ILs) have been suggested as alternatives to organic solvents because of their negligible volatility and flammability at common industrial conditions (Rogers and Seddon 2002; Plechkova and Seddon 2008), which reduce solvent loss and make them inherently safe and environmentally friendly. Ionic liquids (ILs) are salts with low melting points (below 100 °C) composed exclusively of ions (Wasserscheid and Welton 2008; Chiappe and Pieraccini 2005).

2008). 01, and 15 < Reub = ρIDub/μ < 1500. They proposed the following correlation for the estimation of the bubble length based on 148 sets of data Lb ¼ 1:637eÀ0:107 ð1 À eg ÞÀ1:05 ReÀ0:0075 CaÀ0:0687 g ID ð2:2:4Þ Laborie et al. 1, and proposed Eq. 3 2 Literature Review Film Thickness The presence of the film between the dispersed plug and the channel wall offers multiple advantages such as prevention from cross contamination between the segments in biological devices, and enhancement of the heat and mass transfer in chemical engineering processes.

Download PDF sample

Download Studies of Intensified Small-scale Processes for by Dimitrios Tsaoulidis PDF
Rated 4.91 of 5 – based on 24 votes